RESmart BIPAP

700,00   c/iva

Professional precision - Innovative tracking technology ensures accurate and comfortable therapy. - Unique sensitivity setting offers individual therapy algorithm, makes every user get the most comfort. - RESlexTM performs better exhalation and compliance. -Inspiration trigger for auto start-up - Automatic stop after put off mask. - Alert when accidental power-off - In time alert function […]
Free shipping on all purchases to (Continental Portugal)
Ships in 24h/72h
100% secure payment
Description
Additional Info

Professional precision

- Innovative tracking technology ensures accurate and comfortable therapy.

- Unique sensitivity setting offers individual therapy algorithm, makes every user get the most comfort.

- RESlexTM performs better exhalation and compliance.

-Inspiration trigger for auto start-up

- Automatic stop after put off mask.

- Alert when accidental power-off

- In time alert function when mask/tubing off-line

- Automatic leakage and altitude compensation ensure the therapy accuracy anywhere.

 

Ergonomic and powerful design

- Integrated and knock-down designed InH2TM heated humidifier

- DC 24V powered and infrared controlled humidifier make user safe and comfortable.

- Smart Heater automatic restarts after short term break.

- Patented anti-countercurrent water tank.

- Unique Delay-off feature protects RESmart® BPAP from humidity hazard.

- Powerful embedded memory stores last night’s full raw data, 365 nights’ user Blog and more than 30 years’ therapy record.

- User Blog direct output via portable thermal printer.

 

Available Models

- RESmart® BPAP 25

- RESmart® BPAP 25 Auto

- RESmart® BPAP 25T

- RESmart® BPAP 30T

Additional information

Brand

BMC

Dimensions

220 x 194 x 112 mm

Dimensions with INH2O heated humidifier

313 x 194 x 112 mm

Weight

<2,2 kg

Operating temperature

5 to 86ºF

Transport and storage temperature

-4 to 131ºF

Relative humidity operation

≤80% without condensation

Relative humidity transport and storage

≤93% without condensation

Atmospheric pressure operation

860 a 1060 hPa

Atmospheric pressure transport and storage

500 a 1060 hPa

Compliance with standards

IEC 60601-1 General Requirements for the Safety of Medical Electrical Equipment, IEC 60601-1-2 Electromagnetic Compatibility, ISO 17510 Sleep Apnea Breathing Therapy, ISO 8185 General Requirements for Humidification Systems

Energy consumption

100 - 240V AC, 50/60Hz, Máx. 95VA

Type of protection against electric shock

Class II Equipment

Degree of protection against electric shock

Type BF applied part

Degree of protection against ingress of water

Drip-proof, IPX1

Operation Mode

Continuous

RESMART® BPAP 25

Automatic Pressure: No, Function: S, CPAP, Pressure: 4-25 cmH2O

RESMART® BPAP 25A

Automatic Pressure: Available, Function: S, CPAP, Pressure: 4-25 cmH2O

RESMART® BPAP 25T

Automatic Pressure: No, Function: S, CPAP, T, S/T, Pressure: 4-25 cmH2O

RESMART® BPAP 30T

Automatic Pressure: no, Function: S, CPAP, T, S/T, Pressure: 4-30 cmH2O

IPAP Pressure

±1 cmH2O**, 4 to 30 cmH2O*

EPAP Pressure

±1 cmH2O**, 4 to 25 cmH2O*

CPAP Pressure

±1 cmH2O**, 4 to 25 cmH2O*

Respiratory Rate

3 to 40 BPM, Higher than ±1 BPM or ±10% of setting (When measured over a 4 minute period)

E/I Rate

1-6

Max. inspiration time

3.0 seconds

Tilt duration

0 to 60 minutes ±10% of setting

Rise time

0 a 3*** ±25%****

Notes

* Limited to 20 cmH"= when using the Auto feature in mode S, ** Dynamic pressure accuracy is ± 1 cmH20 measured in the patient part of the circuit with a Vio Nasal Mask and variable flow conditions., *** The range of values corresponds to tenths of seconds (for example, a setting of 4 indicates a Raise Time of 0.4 seconds)., **** Measured on the patient's side with an exhalation device Nasal Mask Vio and without patient flow., The static pressure accuracy is ± 0.5 cmH20 measured in the patient part of the circuit with a Vio Nasal Mask and no patient flow.